how nh3 sensor error

Operating Manual PrimaX - Scene7

• Electrochemical sensors are sealed units which contain a corrosive electrolyte. Should a sensor develop leakage, it must be immediately remove d from service and disposed of properly. Caution . PrimaX 6 Safety Regulations GB must be exercised so that the electrolyte does not contact skin, clothing or circuitry otherwise personal injury (burns) and/or equipment damage may result. • The ...

Get Price

Chat With WhatsApp

INFRARED HCFC & AMMONIA (NH3) REFRIGERANT SENSOR User …

Model: HCFC & NH3 IR Sensor IRHCFC&NH3_All Rev: - 6 - Wall Mount. Use locally available wall mounting hardware such as molly-bolts or toggle bolts to firmly affix the sensor to the wall. It is best to use standoffs so there is a slight air gap between the sensor and the wall. The sensor should be mounted using the mounting feet mounted on the back of the housing. Ensure ...

Get Price

Chat With WhatsApp

Instruction and Installation Manual

Locating the EC-FX-NH3 Sensor . Because each sensor is a point measurement, it is very important that the sensor be located properly. One of the most important considerations when installing EC sensors is that they must be easily accessible for calibration and maintenance. As a general rule, locate sensors no closer than one foot from the ceiling. If the primary application is personal ...

Get Price

Chat With WhatsApp

Ammonia Gas Sensor NH3/MR-1000 - Membrapor

omissions or errors herein. Customers should test under their own conditions to ensure that the sensors are suitable for their own requirements. Ammonia Gas Sensor NH3/MR-1000 Electrical Rec. Load Resistor 10 - 33 Ω Bias (V_Sens-V_Ref) not allowed Conformity to RoHS directive RoHS Compliance Environmental Relative Humidity Range 15 % to 90 % RH non-condensing Temperature Range -10 …

Get Price

Chat With WhatsApp

Have legacy AreaRAE NH3 sensor shows "NH3_" on the display ...

There 2 kinds of Ammonia (NH3) sensor made by PN# 008-1118-000 high bias then later RAE developed a non-bias NH3 sensor PH# 008-1125-000. to distinguish between the two the underscore " _ " mark is display for the non-bias -1125 ammonia sensor. the AreaRAE and MultiRAE Plus can take both, you just have to remember update to to the latest firmware and to turn the bias switch off when …

Get Price

Chat With WhatsApp

Ammonia gas detector

Detection of gas: Ammonia ( NH3 ) Measuring range: Resolution: Basic error: Response time: Less than 120 seconds Recovery time: Less than 120 seconds Repeatability: Less than ± 1% The principle of sensor: Electrochemical principle, life for two years Battery: Display: Large screen liquid crystal display To alarm: Acoustic, optical double alarm, can set the alarm value, an alarm ...

Get Price

Chat With WhatsApp

Codes and Design Specifications

GG-NH3-2% 0/2% catalytic bead sensor Compressor Room shutdown GG-VL2-NH3 0/1% vent line sensor HP relief header, above roofline GG-CO2-3% 0/3% infrared sensor CO2 refrigeration systems Room Warning / Alarm setpoints Refrigerated areas 25 ppm / 35 ppm Compressor Room (0-250 ppm) 25 ppm / 150 ppm Compressor Room Shutdown (0-2%) 1% / 2% Vent Line % Carbon Dioxide …

Get Price

Chat With WhatsApp

Ammoniak Sensor! Foto's en eigenschappen — Stal Data

Nieuwe Ammoniak (NH3) sensor! Lees hieronder meer over onze nieuwste ammoniaksensor die over 2 weken te koop is! Industriële NH3 sensor Na verschillende prototypes en sensoren te hebben getest, hebben we de perfecte combinatie gevonden tussen kostprijs en robuustheid. Foto van onze nieuwe NH3 sensor. Onze nieuwe sensor heeft een robuuste behuizing, waardoor die stof en waterdicht is. Ideaal ...

Get Price

Chat With WhatsApp

Ammonia Sensor for Closed-Loop SCR Control

sensor compensation through air humidity only or even calibration based on climate zone where the resultant inaccuracy is tolerated by the control system. To have highest accuracy of the NH 3 sensor, reliable inputs of air humidity and exhaust A/F ratio will be needed for H2O-O2 correction. NO 2 – As a strong oxidizing agent, NO 2 interferes

Get Price

Chat With WhatsApp

Komatsu Error Codes list |

· CA115, engine crankshaft speed sensor and speed sensor malfunction. CA122, the feedback voltage of the intake air pressure sensor is too high. CA123, intake air pressure sensor feedback voltage is too low. CA131, throttle sensor feedback sensor failure. CA132, Throttle Sensor Feedback Pressure and Low Failure.

Get Price

Chat With WhatsApp

NH3-TPD measurements using a zeolite-based sensor - …

· Besides, different sensor concepts for the detection of ammonia have been reported by Satsuma et al [24, 25], Kubinski et al , Moos et al and most recently by the Delphi group . They apply mixed metal oxides or use different measuring concepts, such as mixed potential sensors, which are mainly optimized for SCR applications. For a better understanding of the next sections, the proton …

Get Price

Chat With WhatsApp

Professional gas sensing solution supplier with over 30-year gas sensor manufacturing experience Contact Us